Fountain Colorado Roofing Codes

These are the Fountain Colorado roofing codes. A midroof inspection may not be required. There is a two layer roofing felt underlayment requirement.

Information Updated On

8/22/18

Building Department Phone

719-327-2880

Inspection Line

719-327-2800 Option 2

Permits

719-327-2883

Department Website

Current Building Code

2015 IRC/IBC with RBC amendments

Current Energy Code

2015 International Energy Conservation Code

Requires a Building Permit

Yes, however a permit is not required for repairs less than 100 square feet if being done by homeowner on primary residence.

Roof System/Fire Rating required for Residential Dwellings

Class A

Roof System/Fire Rating required for Commercial Buildings

Class B

Minimum sustained wind speed rating for Asphalt Shingles

100 MPH Sustained/120 MPH 3-second gust

Other wind speed rating

Exposure C

Inspectors carry ladders for the final

Yes, with one story access

Requires midroof (in progress) inspection

Only under certain conditions

Maximum number of layers of asphalt shingles permitted

Existing layers of roof coverings MUST be removed before new asphalt roof coverings can be installed.

Require a sheathing/decking inspection

Yes, if gaps are more than ΒΌ inch

Requires drip edge

Drip edge required at eaves and rake edges of shingle roofs.

Drip edge size minimum

1×2 requirement for commercial properties

Requires Rake/Gable metal edging

No

Enforces the use of Self Adhering Underlayment (i.e., Ice & Water)

Yes above 7,000 feet

Distance inside warm wall

24 inches

Underlayment required 2:12 up to 4:12

Two layers of ASTM D226 roofing felt (half-lapped) required.

Type of valleys allowed

Both

Valley Underlayment/Material required for closed valleys

Either

Valley Underlayment/Material required for open valleys

Either

Kick-out required on Step Flashing

No

Chimney crickets requirement

Not required on re-roofs only on new construction

Requires Soffit eave/vents

Yes